全力为客户提供专业的EMC测试产品和解决方案
The F-170308-1005-1 is used to measure conducted emissions from 10 Hz
– 50 MHz. It can handle 50 amperes of primary power line currents from DC
– 400 Hz without saturating or impacting the transfer impedance.......
The F-170302-1005-1 is used to measure pulse currents.......
The F-2000-40mm-1 is for laboratory and fi eld testing. This probe has a small
outer diameter, approximately 80 mm, with an internal diameter of 40 mm. It
can operate up to 350 amperes of DC – 400 Hz, 3 amperes of CW and 100
amperes of peak pulse curre......
The F-2000-32mm-1 is for laboratory and field testing. This probe has a small
outer diameter, approximately 71 mm, with an internal diameter of 32 mm. It
can operate up to 350 amperes of DC – 400 Hz, 3 amperes of CW and 100
amperes of peak pulse curren......
The F-2000-12mm is ideal for laboratory and fi eld testing from 10 MHz to 3
GHz.......
The F-75B has the advantage of being equipped with a large aperture of 70
mm, making it ideal for large cable bundles. The F-75B can be used to measure
pulse currents up to 100 amperes in magnitude with 800 picosecond risetime
and pulse widths of 40 na......
The F-65A is for laboratory and fi eld testing. It is capable of measuring
pulse transients with risetimes of 200 picoseconds and a pulse width of 3
microseconds. This probe has a small outer diameter, approximately 71 mm
with an internal diameter of 3......
The F-65 is for laboratory and fi eld testing. It is capable of measuring
pulse transients with risetimes of 200 picoseconds and a pulse width of 35
nanoseconds. This probe has a small outer diameter, approximately 71 mm
with an internal diameter of 32......
The F-57 is for laboratory and fi eld testing. A typical calibration curve is
shown below. This Clamp-On Current Probe can be used for the following
specifi cations
● Mil-Std 461F CS114
● Mil-Std. 461F CS115
● Mil-Std. 461F CS116
● DO-160 Section 20......
The F-55A is for laboratory and fi eld testing. It is capable of measuring
pulse transients with risetimes of 800 picoseconds and a pulse width of 3
microseconds. This probe has a small outer diameter, approximately 71 mm,
with an internal diameter of......
The F-52B is a clamp on probe designed for use in measuring RF current
on conductors during EMI test. It is for laboratory use by properly trained RF
technical personnel using best engineering practices......
The F-40-5 has a usable frequency range of 10 Hz – 50 MHz. Primary power
currents of 1000 amperes DC – 400 Hz and 5000 amperes pulse will not alter
the transfer impedance.......
The F-39-4 Current Probe has a split core mechanical design permitting it to
easily clip on and off a conductor. It has an extremely small form factor for
clipping on conductors in small spaces. The F-39-4 off ers a wide bandwidth
measurement capabilit......
The F-39-2 Current Probe has a split core mechanical design permitting it to
easily clip on and off a conductor. It has an extremely small form factor for
clipping on conductors in small spaces. The F-39-2 offers a wide bandwidth
measurement capability......
The F-39-1 Current Probe has a split core mechanical design permitting it to
easily clip on and off a conductor. It has an extremely small form factor for
clipping on conductors in small spaces. The F-39-1 offers a wide bandwidth
measurement capability......
The F-38-4 Current Probe has a split core mechanical design permitting it to
easily clip on and off a conductor. It has an extremely small form factor for
clipping on conductors in small spaces. The F-38-4 offers a wide bandwidth
measurement capability......
The F-38-2 Current Probe has a split core mechanical design permitting it to
easily clip on and off a conductor. It has an extremely small form factor for
clipping on conductors in small spaces. The F-38-2 offers a wide bandwidth
measurement capability......
The F-38-1 Current Probe has a split core mechanical design permitting it to
easily clip on and off a conductor. It has an extremely small form factor for
clipping on conductors in small spaces. The F-38-1 offers a wide bandwidth
measurement capability......
......
......
......
TIA-968-A涉及终端设备测试连接在住宅和商业楼宇。分界点的电信公司的网络和用户网络确定如果TIA-968-A之间应使用或使用另一标准可能更合适。它同样适用于语音频带的模拟,公共交换数字服务和ISDN基本速率接入或基本速率接入系统。
标准TIA-968-A(4.2节)要求测试在电信端口和电源端口进行浪涌冲击试验。终端设备可以是电话机,传真机,调制解调器,语音邮件系统等。
测试需要在其正常工作状态的设备。
PSURGE 8000浪涌测试平台可以执行所有的编程功能要求执行IEC,ITU和测试不需......
哈弗莱测试部门对通过灵活的综合抗扰度测试系统而实现标准要求的测试功能的关注度越来越高。安装的必备功能的灵活性感兴趣。鉴于此原因,HAEFELY 设计了一款具有独特的模块式理念,并且在未来能使客户免去高额投资的测试系统。
此外,要求功能强大,易于操作和随时可用的,且能扩展为多种不同测试应用的传导抗扰度测试系统,能有效的减少产品开发时间。尤其是在电信和工业电子领域,更加强调测试系统的精确性和模块化,模块化意味着以合理的价格实现测试设备的升级且能满足大多数工业领域的需求。
新的AXOS系列是针对这些需求设计......
......
......
......
......
. 满足于 IEC/ EN 6100 0 - 4 - 5 Ed . 1 & 2
. 脉冲电压 5 . 0 kV, 1 . 2 /50 µs
. 脉冲电流 2 . 5 kA, 8/20 µs
. 极性:正/ 负或交替
. 相位同步
. 脉冲电压& 电流监测
. 参数变换功能
. 7” 24 位触摸屏